The FCA includes a see-through cell with a plastic cover that regulates the flow of water and allows the operator to see the tip of the sensors.
The cell includes the following:
-
two 1/2" FPT fittings for the connections to the bypass line,
-
two 1/2" FPT fittings for mounting the sensors,
-
a spigot for water testing,
-
a bleed line to prevent air lock in the cell,
In addition it is also recommended to install a safety switch on the bypass line to prevent accidental feeding of chemicals.
The CHEMTROL 255 PPM/pH Digital Controller automatically maintains both sanitizer PPM and water pH in pools and spas.
All operating functions are clearly labeled and accessible from the front panel, with many safety and easy-reset features not found on other controllers:

pH calibration from 7 to 8,

PPM setpoint from 0.1 to 10.0 ppm or mg/l (or 0.01 to 2.0 optional),

pH setpoint from 7 to 8,

Chlorine and pH feed modes: off, manual, automatic,

PPM and pH proportional control bandwidth from 0 to 100% of the setpoint,

Chlorine high and low alarms from 400 to 900 mV,

pH high and low alarms from 4 to 10,

Chlorine overfeed safety timer from 0 to 999 minutes,

pH overfeed safety timer from 0 to 99 minutes.
To select a function, simply press PPM or pH and then the desired function. The display shows the current function value. Use the UP or DOWN arrows to adjust to the desired value.
CONTROL SETPOINTS
The standard factory-set Chlorine control level is 1.0 ppm or mg/l, based on WORLD HEALTH ORGANIZATION (WHO) and NATIONAL SPA AND POOL INSTITUTE (NSPI) values for prevention of germs and bacteria. A range of 0.01 to 2.0 is also available for low chlorine level applications.
The standard factory-set pH control level is 7.5. Below 7.4, the water causes eye irritation and corrosion of equipment. Above 7.6, it also causes eye irritation plus water cloudiness, scaling, stains and reduced sanitizer efficiency.
To change the control levels, the operator presses PPM or pH and then SETPOINT. Use the UP or DOWN arrows to adjust the PPM and pH setpoints. To save the new setpoint value and exit, press SETPOINT again.
The controller then automatically activates the chemical feeders for sanitizer and acid (or soda) feed, as required to maintain the set PPM and pH levels - regardless of fluctuations in bather load, contamination and weather. Like a thermostat maintaining a constant temperature, it prevents overfeeding or underfeeding, both of which are detrimental to good water quality.
ALARMS
When there is an alarm condition, the corresponding display flashes the alarm value:

PPM out-of-range,

pH out-of-range,

PPM overfeed,

pH overfeed.
The display stops flashing when the condition is corrected. To reset the overfeed timers, turn the feed mode to off and then back to Manual or Auto.
RESET
The ideal values are set as default values. They can be adjusted by the operator at any time. To reset all factory default values, press PPM and pH for 5 seconds.
SPECIFICATION
|
FREE CHLORINE CONTROL |
Adjustable from 0.1 to 10.0 ppm (mg/l) or 0.01 to 2.0 (specify). |
|
pH CONTROL |
Adjustable from 4.0 to 10.0 |
|
FREE CHLORINE SENSOR |
Solid state electrode with 10-ft (3 m) cable |
|
pH SENSOR |
Glass electrode with 10-ft (3 m) cable |
|
READOUTS |
PPM (3 digits) and pH (2 digits) LEDs |
|
FEED MODES |
Manual, automatic, proportional |
|
ADJUSTMENTS |
Setpoint, calibration, limits, feed rate |
|
INDICATORS |
LEDs for feed mode, feed status, alarms |
|
SAFETY |
Audio, visual and remote alarms
Out-of-range limits and overfeed safety timers |
|
CABINET |
Polystyrene 9x7x4 in. (22x18x10 cm) |
|
ELECTRICAL |
110V, 230V or 24 VAC (specify) |
|
PLUMBING |
PVC tees for 1-1/2" or 2" line |
|
WARRANTY |
5 years on electronic module 1 year on all other parts |
|
SHIPPING |
12x12x12-in (30x30x30 cm) carton
8 lbs (3 kg) without pumps
16 lbs (6 kg) with 2 chemical feed pumps |
A SOUND INVESTMENT
The CHEMTROL 255 controller is based on 20+ years of experience in pool and spa automation with over 25,000 installations worldwide. Featuring a 5-year electronics warranty, it actually pays for itself in 1 to 2 years through cost savings in operating and maintenance expenses.
Savings continue to accrue from the more efficient use of chemicals, avoiding over- and underfeeding, and from lower labour costs for water testing and repairs of damaged equipment. In particular, commercial operators save on speciality chemicals, customer complaints and health department shutdowns.
Download PDF brochure of our Epic Chemtrol Chemical Controllers